Bitzer Ecolite A2L Condensing Unit LHL5E/4EES-4Y c/w OLC-K1 low level oil switch
Product code:
BZCU28-203
Manufacturer code
LHL5E/4EES-4Y
Product Group : | Outdoor Semi Hermetic Condensing Units |
---|
General
Product Group : | Outdoor Semi Hermetic Condensing Units |
---|
Additional Info
Family : | Ecolite |
---|
Compressor
Compressor Model : | 4EES-4 |
---|---|
Power Supply Compressor : | 400/3/50 V/Ph/Hz |
Connections
Liquid Line Connection : | 5/8 in, 16 mm |
---|---|
Suction Line Connection : | 1 1/8 in, 28 mm |
Cooling Capacity R448A/R449A
R448A/R449A Cooling Capacity -35°C : | 2963 W |
---|
Electrical
LRA : | 53.5 A |
---|---|
MCC : | 12.2 A |
Power Supply : | 400/3/50 V/Ph/Hz |
Fan
Fan Blade Size : | 450 mm |
---|---|
Fan Diameter : | 450 mm |
Fan Size : | 450 mm |
Number Of Fans : | 2 |
Power Supply Fan : | 230/1/50 V/Ph/Hz |
General Information
Application : | LBP/MBP/Fridge.Freezer |
---|---|
Model Number : | LHL5E-4EES-4Y |
Receiver Volume : | 15 L |
Measurements
Height : | 1230 mm |
---|---|
Length : | 450 mm |
Net Weight : | 210 kg |
Weight : | 210 kg |
Width : | 1300 mm |
R448A/R449A Performances
R448A/R449A Cooling Capacity -10°C : | 11442 W |
---|---|
R448A/R449A Cooling Capacity -25°C : | 5749 W |
R513A Performances
R513A Cooling Capacity Rated -10°C : | 7560 W |
---|---|
R513A Cooling Capacity Rated 0°C : | 11339 W |
R513A Cooling Capacity Rated 5°C : | 13611 W |
Refrigerant
GWP : | 631 |
---|---|
Refrigerant : | R134a, R407A, R407C, R407F, R448A, R449A, R450A, R454C, R455A, R513A, R1234yf |
Sound Power/Pressure
Sound Pressure Level 50 Hz 10m : | 42.5 dB(A) |
---|
Product information
ECOLITE is a fully equipped "plug and play" air-cooled unit for indoor or outdoor installation, made for DX applications. Capacity control (10-100% LHL5; 50-100% LHL3) provides smooth and energy efficient operation even with large load variations. The same model can be used for both refrigeration and freezing applications.
A1 refrigerants: R448A, R449A, R450A, R513A, R134a, R407A, R407C, R407F.
A2L refrigerants (GWP<150) that can be used: R1234yf, R1234ze, R454C, R455A.
EN 378 and the Swedish Cooling Standard provide good guidance for safe installation and operation.
For information and data, contact Kylma.
A1 refrigerants: R448A, R449A, R450A, R513A, R134a, R407A, R407C, R407F.
A2L refrigerants (GWP<150) that can be used: R1234yf, R1234ze, R454C, R455A.
EN 378 and the Swedish Cooling Standard provide good guidance for safe installation and operation.
For information and data, contact Kylma.
File name | Extension | Size |
---|---|---|
Brochures | 969.47 KB |
Product Number | Manufacturer product number | Technical data | Price | Availability |
---|---|---|---|---|
LHL3E/2DES-2Y
|
Bitzer Ecolite A2L Condensing Unit LHL3E/2DES-2Y c/w OLC-K1 low level oil switch
|
Available after log in
|
Available after log in
|
|
LHL5E/4EES-4Y
|
Bitzer Ecolite A2L Condensing Unit LHL5E/4EES-4Y c/w OLC-K1 low level oil switch
|
Available after log in
|
Available after log in
|
|
LHL5E/4CES-6Y
|
Bitzer Ecolite A2L Condensing Unit LHL5E/4CES-6Y c/w OLC-K1 low level oil switch
|
Available after log in
|
Available after log in
|
|
LHL5E/4FES-3Y
|
Bitzer Ecolite A2L Condensing Unit LHL5E/4FES-3Y c/w OLC-K1 low level oil switch
|
Available after log in
|
Available after log in
|
|
LHL5E/4DES-5Y
|
Bitzer Ecolite A2L Condensing Unit LHL5E/4DES-5Y c/w OLC-K1 low level oil switch
|
Available after log in
|
Available after log in
|